S.DECANTER

DECANTER OF DAI HUNG
 
After the microbiological treatment process, the output wastewater has a small amount of floc on the surface, affecting the output quality of the wastewater. Because of this, the DECANTER is applied to solve the separation of the clean water in the surface of tank and the suspended sludge, minimizing the use of sedimentation tank.
S.Decanter is a product of Dai Hung designed to serve the collection of surface water after treatment in wastewater treatment systems, normally applied in the design of SBR tanks.


S.Decanter is designed with 2 different type for specific application:
Fix type;
Float type;

Device selection

Tank size
Fluids
 
Q&A

-> An industrial exhaust fan is designed to remove air, heat, and fumes from a workspace, while a centrifugal fan uses centrifugal force to move air efficiently through ducts or systems. Centrifugal fans are commonly used in dust collection and ventilation systems requiring high pressur

-> A gas scrubber is typically used to treat acidic or chemical exhaust gases such as SO₂, HCl, NH₃, and VOCs. Depending on the scrubbing solution and design, it can also capture particulates and neutralize harmful emissions from industrial processes

-> A high-quality submersible mixer typically lasts between 5 to 10 years, depending on material quality, operating conditions, and maintenance frequency. Using stainless steel materials and regular servicing can extend the mixer’s lifetime

-> A belt filter press can process between 5 to 50 cubic meters of sludge per day, depending on sludge concentration, belt width, and machine capacity. Proper conditioning and polymer dosing improve dehydration efficiency

-> Yes, a DAF system is highly effective in separating oil, grease, and suspended solids from food-processing wastewater. By injecting microbubbles, it floats contaminants to the surface for removal, improving overall treatment efficiency
DECANTER – FLOAT TYPE
Float type Decanter is designed with sensor, pneumatic and PLC control to control the water collector to collect output water through the next stage of treatment.

Application
•Apply for biological tank with flexible water level;

Model Spec FLowrate L2 D2
Name m3/h m mm
S.Decanter – 120Fl  
Power: 0.25-0.55kW
Operation: Controlled by PLC and sensor
Application: Flexible water level
 
 
120 2.1 90
S.Decanter – 250Fl 250 2.9 90
S.Decanter – 400Fl 400 5.0 125
S.Decanter – 600Fl 600 5.0 125
S.Decanter – 10000Fl 1.000 5.0 150
S.Decanter – 1400Fl 1.600 5.0 150
S.Decanter – 2000Fl 2.000 5.0 200


DECANTER – FIXED TYPE
Fixed Decanter system is designed with pneumatic control and PLC, to control the water trough to collect input water through the next stage of treatment.

Application
•Applying for biological tank with fixed water level;

 
Model Spec Flowrate L DN1 n DN2
Name m3/h mm mm   mm
S.Decanter – 120F  
Power: 0.37kW
Operation: controlled by pneumatic and PLC
Application: fixed water level
 
 
120 2000 150 2 42
S.Decanter – 250F 250 3000 150 3 42
S.Decanter – 400F 400 4000 200 3 42
S.Decanter – 600F 600 6000 200 4 60
S.Decanter – 10000F 1.000 8000 250 4 60
S.Decanter – 1400F 1.600 10000 250 6 60
S.Decanter – 2000F 2.000 12000 250 8 60
Bạn đã không sử dụng Site, Bấm vào đây để duy trì trạng thái đăng nhập. Thời gian chờ: 60 giây